Eaton HCM1A0503V2-4R7-R 4.7 uH AEC-Q200 Inductor, 4.1 A
Eaton HCM1A0503V2-4R7-R 4.7 uH AEC-Q200 Inductor, 4.1 A

Eaton HCM1A0503V2-4R7-R 4.7 uH AEC-Q200 Inductor, 4.1 A

Share
Eaton HCM1A0503V2-4R7-R: AEC-Q200 automotive power inductor, 4.7 uH ±20%, 4.1 A Irms, Isat 6 A, DCR 41 mOhm, 5.7 x 5.4 mm.
    • Product Details
    • Download

    Eaton HCM1A0503V2-4R7-R 4.7 uH AEC-Q200 Inductor, 4.1 A

    HCM1A0503V2-4R7-R at a glance: AEC-Q200 automotive power inductor, 4.7 uH ±20%, 4.1 A Irms, Isat 6 A (20% rolloff @ +25 °C), DCR 41 mOhm, 5.7 x 5.4 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCM1A0503V2-4R7-R
    OCL (open circuit inductance)4.7 uH ±20%
    FLL minimum, at Isat3 uH
    Irms (DC, 40 °C rise)4.1 A
    Isat (20% rolloff @ +25 °C)6 A
    DCR typical @ +20 °C41 mOhm
    DCR maximum @ +20 °C47 mOhm
    SRF typical22 MHz
    K-factor (Bp-p = K x L x dI)367, Bp-p in Gauss
    Package5.7 x 5.4 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10910

    Outline Drawing

    HCM1A0503V2-4R7-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10910: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    Copper loss at the rated current works out to roughly 0.689 W from a typical DCR of 41 mOhm at 4.1 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    At Isat the part holds about 84.6 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    The K-factor of 367 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 1,725 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Self-resonant frequency is 22 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Where This Series Fits

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    The HCM1A0503V2 family spans 0.2 uH to 10 uH; this row sits at position 12 of 15.

    One step down the table, HCM1A0503V2-3R3-R, sits at 3.3 uH with 4.7 A and 32 mOhm – the lower inductance buys about 1.1 A of extra current in the same body.

    • Core material: alloy powder core, 5.7 x 5.4 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 47 mOhm becomes roughly 71.9 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check the hot-corner saturation margin against the worst-case load step.
    • Verify the part marking for revision traceability in production.
    • Check the hot-corner saturation margin against the worst-case load step.

    Frequently Asked Questions

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Why do V2 and V3 parts exist?
    They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products