| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0503V3-4R7-R |
| OCL (open circuit inductance) | 4.7 uH ±20% |
| FLL minimum, at Isat | 3 uH |
| Irms (DC, 40 °C rise) | 4.1 A |
| Isat (20% rolloff @ +25 °C) | 6 A |
| DCR typical @ +20 °C | 41 mOhm |
| DCR maximum @ +20 °C | 47 mOhm |
| SRF typical | 22 MHz |
| K-factor (Bp-p = K x L x dI) | 337, Bp-p in Gauss |
| Package | 5.7 x 5.4 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1483 |

Drawing reproduced from Eaton Technical Data ELX1483: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.
With 41 mOhm typical, the I-squared-R loss at the full 4.1 A rating is about 0.689 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
At Isat the part holds about 84.6 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
K-factor 337 means the flux swing is about 1,584 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
Self-resonant frequency is 22 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Within the HCM1A0503V3 family this is value 12 of 15, in a range that runs from 0.2 uH to 10 uH.
One step down the table, HCM1A0503V3-3R3-R, sits at 3.3 uH with 4.7 A and 32 mOhm – the lower inductance buys about 1.1 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 47 mOhm becomes roughly 71.9 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What does AEC-Q200 cover?
The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.
Why do V2 and V3 parts exist?
They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.