Eaton HCM1A0503V3-6R8-R 6.8 uH Automotive Power Inductor
Eaton HCM1A0503V3-6R8-R 6.8 uH Automotive Power Inductor

Eaton HCM1A0503V3-6R8-R 6.8 uH Automotive Power Inductor

Share
Eaton HCM1A0503V3-6R8-R: AEC-Q200 automotive power inductor, 6.8 uH ±20%, 3.3 A Irms, Isat 4 A, DCR 61 mOhm, 5.7 x 5.4 mm.
    • Product Details
    • Download

    Eaton HCM1A0503V3-6R8-R 6.8 uH Automotive Power Inductor

    HCM1A0503V3-6R8-R at a glance: AEC-Q200 automotive power inductor, 6.8 uH ±20%, 3.3 A Irms, Isat 4 A (20% rolloff @ +25 °C), DCR 61 mOhm, 5.7 x 5.4 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCM1A0503V3-6R8-R
    OCL (open circuit inductance)6.8 uH ±20%
    FLL minimum, at Isat4.35 uH
    Irms (DC, 40 °C rise)3.3 A
    Isat (20% rolloff @ +25 °C)4 A
    DCR typical @ +20 °C61 mOhm
    DCR maximum @ +20 °C70 mOhm
    SRF typical16 MHz
    K-factor (Bp-p = K x L x dI)219, Bp-p in Gauss
    Package5.7 x 5.4 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1483

    Dimensions and Pad Layout

    HCM1A0503V3-6R8-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1483: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    The DCR figure of 61 mOhm is what sets the efficiency: at 3.3 A the winding drops about 0.201 mV and dissipates 0.664 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    At Isat the part holds about 54.4 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    The K-factor of 219 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 1,489 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Self-resonant frequency is 16 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Positioning in the Range

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Within the HCM1A0503V3 family this is value 14 of 15, in a range that runs from 0.2 uH to 10 uH.

    The next value up in the same family, HCM1A0503V3-100-R, gives 10 uH at 2.8 A and DCR 90 mOhm: the extra inductance costs about 0.8 A of rated current.

    • Core material: alloy powder core, 5.7 x 5.4 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 70 mOhm becomes roughly 107 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.
    • Verify the qualification and the mounting process match the assembly line.
    • Check Isat and DCR at the hot corner, not at +20 °C.

    Frequently Asked Questions

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.

    Why do V2 and V3 parts exist?
    They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.