Eaton HCM1A0503V3-R33-R 0.33 uH AEC-Q200 Inductor, 14 A
Eaton HCM1A0503V3-R33-R 0.33 uH AEC-Q200 Inductor, 14 A

Eaton HCM1A0503V3-R33-R 0.33 uH AEC-Q200 Inductor, 14 A

Share
Eaton HCM1A0503V3-R33-R: AEC-Q200 automotive power inductor, 0.33 uH ±20%, 14 A Irms, Isat 16 A, DCR 2.9 mOhm, 5.7 x 5.4 mm.
    • Product Details
    • Download

    Eaton HCM1A0503V3-R33-R 0.33 uH AEC-Q200 Inductor, 14 A

    HCM1A0503V3-R33-R at a glance: AEC-Q200 automotive power inductor, 0.33 uH ±20%, 14 A Irms, Isat 16 A (20% rolloff @ +25 °C), DCR 2.9 mOhm, 5.7 x 5.4 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1A0503V3-R33-R
    OCL (open circuit inductance)0.33 uH ±20%
    FLL minimum, at Isat0.211 uH
    Irms (DC, 40 °C rise)14 A
    Isat (20% rolloff @ +25 °C)16 A
    DCR typical @ +20 °C2.9 mOhm
    DCR maximum @ +20 °C3.4 mOhm
    SRF typical120 MHz
    K-factor (Bp-p = K x L x dI)1,119, Bp-p in Gauss
    Package5.7 x 5.4 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1483

    Mechanical Drawing

    HCM1A0503V3-R33-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1483: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    With 2.9 mOhm typical, the I-squared-R loss at the full 14 A rating is about 0.568 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    The core stores roughly 42.2 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    With K = 1,119, a peak-to-peak ripple of one amp produces roughly 369 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 120 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Positioning in the Range

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    In the HCM1A0503V3 line-up this part is number 3 of 15 by inductance, between 0.2 uH and 10 uH.

    Compared with its neighbours in the table, HCM1A0503V3-R35-R trades 1.8 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: alloy powder core, 5.7 x 5.4 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Putting It to Work

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 3.4 mOhm becomes roughly 5.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check the hot-corner saturation margin against the worst-case load step.
    • Confirm the qualification file covers the module-level test plan.
    • Verify the part marking for revision traceability in production.

    Frequently Asked Questions

    What does AEC-Q200 cover?
    The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.

    Why do V2 and V3 parts exist?
    They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Shenzhen Gaorunxin Technology Co., Ltd