Eaton HCM1A0703-2R2-R 2.2 uH Shielded Automotive Inductor
Eaton HCM1A0703-2R2-R 2.2 uH Shielded Automotive Inductor

Eaton HCM1A0703-2R2-R 2.2 uH Shielded Automotive Inductor

Share
Eaton HCM1A0703-2R2-R: AEC-Q200 automotive power inductor, 2.2 uH ±20%, 5.7 A Irms, Isat 10 A, DCR 18 mOhm, 7.4 x 7 mm.
    • Product Details
    • Download

    Eaton HCM1A0703-2R2-R 2.2 uH Shielded Automotive Inductor

    HCM1A0703-2R2-R at a glance: AEC-Q200 automotive power inductor, 2.2 uH ±20%, 5.7 A Irms, Isat 10 A (20% rolloff @ +25 °C), DCR 18 mOhm, 7.4 x 7 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1A0703-2R2-R
    OCL (open circuit inductance)2.2 uH ±20%
    FLL minimum, at Isat1.4 uH
    Irms (DC, 40 °C rise)5.7 A
    Isat (20% rolloff @ +25 °C)10 A
    DCR typical @ +20 °C18 mOhm
    DCR maximum @ +20 °C20 mOhm
    K-factor (Bp-p = K x L x dI)309, Bp-p in Gauss
    Package7.4 x 7 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10548

    Mechanical Drawing

    HCM1A0703-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10548: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.

    At the rated 5.7 A the winding dissipates about 0.585 W in copper alone, using the typical DCR of 18 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    Stored energy at Isat is about 110 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    K-factor 309 means the flux swing is about 680 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Where This Series Fits

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Within the HCM1A0703 family this is value 11 of 19, in a range that runs from 0.1 uH to 33 uH.

    One step down the table, HCM1A0703-1R2-R, sits at 1.2 uH with 7.8 A and 9.3 mOhm – the lower inductance buys about 2.9 A of extra current in the same body.

    • Core material: alloy powder core, 7.4 x 7 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 20 mOhm becomes roughly 30.6 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Verify the part marking for revision traceability in production.
    • Check the hot-corner saturation margin against the worst-case load step.

    Frequently Asked Questions

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products