| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0703-3R3-R |
| OCL (open circuit inductance) | 3.3 uH ±20% |
| FLL minimum, at Isat | 2.1 uH |
| Irms (DC, 40 °C rise) | 4.9 A |
| Isat (20% rolloff @ +25 °C) | 9 A |
| DCR typical @ +20 °C | 28 mOhm |
| DCR maximum @ +20 °C | 30 mOhm |
| K-factor (Bp-p = K x L x dI) | 262, Bp-p in Gauss |
| Package | 7.4 x 7 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10548 |

Drawing reproduced from Eaton Technical Data 10548: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.
The DCR figure of 28 mOhm is what sets the efficiency: at 4.9 A the winding drops about 0.137 mV and dissipates 0.672 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
At Isat the part holds about 134 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
With K = 262, a peak-to-peak ripple of one amp produces roughly 865 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Within the HCM1A0703 family this is value 12 of 19, in a range that runs from 0.1 uH to 33 uH.
The next value up in the same family, HCM1A0703-4R7-R, gives 4.7 uH at 4.1 A and DCR 37 mOhm: the extra inductance costs about 1.6 A of rated current.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 30 mOhm becomes roughly 45.9 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
Why do V2 and V3 parts exist?
They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
Shenzhen Gaorunxin Technology Co., Ltd