| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0703-R15-R |
| OCL (open circuit inductance) | 0.15 uH ±20% |
| FLL minimum, at Isat | 0.09 uH |
| Irms (DC, 40 °C rise) | 18.5 A |
| Isat (20% rolloff @ +25 °C) | 36 A |
| DCR typical @ +20 °C | 1.5 mOhm |
| DCR maximum @ +20 °C | 1.8 mOhm |
| K-factor (Bp-p = K x L x dI) | 1,358, Bp-p in Gauss |
| Package | 7.4 x 7 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10548 |

Drawing reproduced from Eaton Technical Data 10548: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.
Copper loss at the rated current works out to roughly 0.513 W from a typical DCR of 1.5 mOhm at 18.5 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
At Isat the part holds about 97.2 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
The K-factor of 1,358 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 204 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
In the HCM1A0703 line-up this part is number 2 of 19 by inductance, between 0.1 uH and 33 uH.
One step down the table, HCM1A0703-R10-R, sits at 0.10 uH with 22 A and 1.2 mOhm – the lower inductance buys about 5 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 1.8 mOhm becomes roughly 2.75 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
Why do V2 and V3 parts exist?
They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd