Eaton HCM1A0703V2-4R7-R: AEC-Q200 automotive power inductor, 4.7 uH ±20%, 4 A Irms, Isat 6.8 A, DCR 40.3 mOhm, 7.3 x 6.8 mm.
    • Product Details
    • Download

    Eaton HCM1A0703V2-4R7-R 4.7 uH AEC-Q200 Inductor, 4 A

    HCM1A0703V2-4R7-R at a glance: AEC-Q200 automotive power inductor, 4.7 uH ±20%, 4 A Irms, Isat 6.8 A (20% rolloff @ +25 °C), DCR 40.3 mOhm, 7.3 x 6.8 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCM1A0703V2-4R7-R
    OCL (open circuit inductance)4.7 uH ±20%
    FLL minimum, at Isat3 uH
    Irms (DC, 40 °C rise)4 A
    Isat (20% rolloff @ +25 °C)6.8 A
    DCR typical @ +20 °C40.3 mOhm
    DCR maximum @ +20 °C46.5 mOhm
    SRF typical20 MHz
    K-factor (Bp-p = K x L x dI)227, Bp-p in Gauss
    Package7.3 x 6.8 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10911

    Mechanical Drawing

    HCM1A0703V2-4R7-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10911: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.

    Copper loss at the rated current works out to roughly 0.645 W from a typical DCR of 40.3 mOhm at 4 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    Stored energy at Isat is about 109 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    K-factor 227 means the flux swing is about 1,067 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Self-resonant frequency is 20 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Where This Series Fits

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Of the 20 values listed for HCM1A0703V2, this is the 14th, in a family covering 0.1 uH to 33 uH.

    One step down the table, HCM1A0703V2-3R3-R, sits at 3.3 uH with 5 A and 24.5 mOhm – the lower inductance buys about 1.4 A of extra current in the same body.

    • Core material: alloy powder core, 7.3 x 6.8 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 46.5 mOhm becomes roughly 71.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Verify the part marking for revision traceability in production.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.
    • Verify the qualification and the mounting process match the assembly line.

    Frequently Asked Questions

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products