| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0703V3-2R2-R |
| OCL (open circuit inductance) | 2.2 uH ±20% |
| FLL minimum, at Isat | 1.4 uH |
| Irms (DC, 40 °C rise) | 7 A |
| Isat (20% rolloff @ +25 °C) | 8.5 A |
| DCR typical @ +20 °C | 12.5 mOhm |
| DCR maximum @ +20 °C | 15.5 mOhm |
| SRF typical | 29 MHz |
| K-factor (Bp-p = K x L x dI) | 373, Bp-p in Gauss |
| Package | 7.3 x 6.8 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1484 |

Drawing reproduced from Eaton Technical Data ELX1484: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.
With 12.5 mOhm typical, the I-squared-R loss at the full 7 A rating is about 0.613 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
At Isat the part holds about 79.5 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
The K-factor of 373 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 821 Gauss of Bp-p, the figure the core-loss curve is plotted against.
Self-resonant frequency is 29 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
In the HCM1A0703V3 line-up this part is number 12 of 20 by inductance, between 0.1 uH and 33 uH.
Compared with its neighbours in the table, HCM1A0703V3-3R3-R trades 3.5 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 15.5 mOhm becomes roughly 23.7 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
Why do V2 and V3 parts exist?
They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd