| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0703V3-3R3-R |
| OCL (open circuit inductance) | 3.3 uH ±20% |
| FLL minimum, at Isat | 2.1 uH |
| Irms (DC, 40 °C rise) | 5 A |
| Isat (20% rolloff @ +25 °C) | 7.5 A |
| DCR typical @ +20 °C | 24.5 mOhm |
| DCR maximum @ +20 °C | 28.5 mOhm |
| SRF typical | 25 MHz |
| K-factor (Bp-p = K x L x dI) | 305, Bp-p in Gauss |
| Package | 7.3 x 6.8 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1484 |

Drawing reproduced from Eaton Technical Data ELX1484: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.
With 24.5 mOhm typical, the I-squared-R loss at the full 5 A rating is about 0.613 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
Energy storage at the saturation current is around 92.8 uJ, the number that connects the inductance and the current rating into a single transient figure.
With K = 305, a peak-to-peak ripple of one amp produces roughly 1,006 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
Self-resonant frequency is 25 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Within the HCM1A0703V3 family this is value 13 of 20, in a range that runs from 0.1 uH to 33 uH.
One step down the table, HCM1A0703V3-2R2-R, sits at 2.2 uH with 7 A and 12.5 mOhm – the lower inductance buys about 3 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 28.5 mOhm becomes roughly 43.6 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What is the operating temperature range?
The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd