| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0805V2-220-R |
| OCL (open circuit inductance) | 22 uH ±20% |
| FLL minimum, at Isat | 14 uH |
| Irms (DC, 40 °C rise) | 3.5 A |
| Isat (20% rolloff @ +25 °C) | 4 A |
| DCR typical @ +20 °C | 60.7 mOhm |
| DCR maximum @ +20 °C | 70 mOhm |
| SRF typical | 6.5 MHz |
| K-factor (Bp-p = K x L x dI) | 53, Bp-p in Gauss |
| Package | 8.4 x 8 mm |
| Height | 5.4 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10902 |

Drawing reproduced from Eaton Technical Data 10902: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.
Copper loss at the rated current works out to roughly 0.744 W from a typical DCR of 60.7 mOhm at 3.5 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
Energy storage at the saturation current is around 176 uJ, the number that connects the inductance and the current rating into a single transient figure.
The K-factor of 53 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 1,166 Gauss of Bp-p, the figure the core-loss curve is plotted against.
Self-resonant frequency is 6.5 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
The HCM1A0805V2 family spans 0.22 uH to 47 uH; this row sits at position 10 of 12.
One step down the table, HCM1A0805V2-150-R, sits at 15 uH with 4 A and 43 mOhm – the lower inductance buys about 1.3 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 70 mOhm becomes roughly 107 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
What is the operating temperature range?
The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.
Why do V2 and V3 parts exist?
They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd