Eaton HCM1A0805V2-2R2-R 2.2 uH Shielded Automotive Inductor
Eaton HCM1A0805V2-2R2-R 2.2 uH Shielded Automotive Inductor

Eaton HCM1A0805V2-2R2-R 2.2 uH Shielded Automotive Inductor

Share
Eaton HCM1A0805V2-2R2-R: AEC-Q200 automotive power inductor, 2.2 uH ±20%, 10.5 A Irms, Isat 9.6 A, DCR 7 mOhm, 8.4 x 8 mm.
    • Product Details
    • Download

    Eaton HCM1A0805V2-2R2-R 2.2 uH Shielded Automotive Inductor

    HCM1A0805V2-2R2-R at a glance: AEC-Q200 automotive power inductor, 2.2 uH ±20%, 10.5 A Irms, Isat 9.6 A (20% rolloff @ +25 °C), DCR 7 mOhm, 8.4 x 8 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCM1A0805V2-2R2-R
    OCL (open circuit inductance)2.2 uH ±20%
    FLL minimum, at Isat1.41 uH
    Irms (DC, 40 °C rise)10.5 A
    Isat (20% rolloff @ +25 °C)9.6 A
    DCR typical @ +20 °C7 mOhm
    DCR maximum @ +20 °C8.5 mOhm
    SRF typical23 MHz
    K-factor (Bp-p = K x L x dI)174, Bp-p in Gauss
    Package8.4 x 8 mm
    Height5.4 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10902

    Outline Drawing

    HCM1A0805V2-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10902: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.

    At the rated 10.5 A the winding dissipates about 0.772 W in copper alone, using the typical DCR of 7 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    At Isat the part holds about 101 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    The K-factor of 174 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 383 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Self-resonant frequency is 23 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Where This Series Fits

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    The HCM1A0805V2 family spans 0.22 uH to 47 uH; this row sits at position 5 of 12.

    The next value up in the same family, HCM1A0805V2-3R3-R, gives 3.3 uH at 9.2 A and DCR 9 mOhm: the extra inductance costs about 4.8 A of rated current.

    • Core material: alloy powder core, 8.4 x 8 mm body at 5.4 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 8.5 mOhm becomes roughly 13 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check the hot-corner saturation margin against the worst-case load step.
    • Check the hot-corner saturation margin against the worst-case load step.
    • Check the hot-corner saturation margin against the worst-case load step.

    Frequently Asked Questions

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Why do V2 and V3 parts exist?
    They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products