| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0805V2-R68-R |
| OCL (open circuit inductance) | 0.68 uH ±20% |
| FLL minimum, at Isat | 0.43 uH |
| Irms (DC, 40 °C rise) | 17 A |
| Isat (20% rolloff @ +25 °C) | 22 A |
| DCR typical @ +20 °C | 2.73 mOhm |
| DCR maximum @ +20 °C | 3.5 mOhm |
| SRF typical | 70 MHz |
| K-factor (Bp-p = K x L x dI) | 288, Bp-p in Gauss |
| Package | 8.4 x 8 mm |
| Height | 5.4 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10902 |

Drawing reproduced from Eaton Technical Data 10902: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.
With 2.73 mOhm typical, the I-squared-R loss at the full 17 A rating is about 0.789 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
The core stores roughly 165 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
K-factor 288 means the flux swing is about 196 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
Self-resonant frequency is 70 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
In the HCM1A0805V2 line-up this part is number 3 of 12 by inductance, between 0.22 uH and 47 uH.
Compared with its neighbours in the table, HCM1A0805V2-1R0-R trades 5 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 3.5 mOhm becomes roughly 5.36 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd