Eaton HCM1A1104-101-R AEC-Q200 Inductor 100 uH, Isat 2 A
Eaton HCM1A1104-101-R AEC-Q200 Inductor 100 uH, Isat 2 A

Eaton HCM1A1104-101-R AEC-Q200 Inductor 100 uH, Isat 2 A

Share
Eaton HCM1A1104-101-R: AEC-Q200 automotive power inductor, 100 uH ±20%, 1.5 A Irms, Isat 2 A, DCR 270 mOhm, 11.5 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1A1104-101-R AEC-Q200 Inductor 100 uH, Isat 2 A

    HCM1A1104-101-R at a glance: AEC-Q200 automotive power inductor, 100 uH ±20%, 1.5 A Irms, Isat 2 A (20% rolloff @ +25 °C), DCR 270 mOhm, 11.5 x 10.3 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1A1104-101-R
    OCL (open circuit inductance)100 uH ±20%
    FLL minimum, at Isat64 uH
    Irms (DC, 40 °C rise)1.5 A
    Isat (20% rolloff @ +25 °C)2 A
    DCR typical @ +20 °C270 mOhm
    DCR maximum @ +20 °C300 mOhm
    K-factor (Bp-p = K x L x dI)26, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10550

    Mechanical Dimensions & Pad Layout

    HCM1A1104-101-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10550: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.

    At the rated 1.5 A the winding dissipates about 0.608 W in copper alone, using the typical DCR of 270 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    Stored energy at Isat is about 200 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    With K = 26, a peak-to-peak ripple of one amp produces roughly 2,600 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Where This Series Fits

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    In the HCM1A1104 line-up this part is number 19 of 19 by inductance, between 0.2 uH and 100 uH.

    One step down the table, HCM1A1104-470-R, sits at 47 uH with 1.9 A and 165 mOhm – the lower inductance buys about 0 A of extra current in the same body.

    • Core material: alloy powder core, 11.5 x 10.3 mm body at 4.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 300 mOhm becomes roughly 459 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.
    • Confirm the qualification file covers the module-level test plan.

    Frequently Asked Questions

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products