| Parameter | Value |
|---|---|
| Orderable part number | HCM1A1104-220-R |
| OCL (open circuit inductance) | 22 uH ±20% |
| FLL minimum, at Isat | 14.1 uH |
| Irms (DC, 40 °C rise) | 3.2 A |
| Isat (20% rolloff @ +25 °C) | 6 A |
| DCR typical @ +20 °C | 58 mOhm |
| DCR maximum @ +20 °C | 65 mOhm |
| K-factor (Bp-p = K x L x dI) | 64, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 4.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10550 |

Drawing reproduced from Eaton Technical Data 10550: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.
With 58 mOhm typical, the I-squared-R loss at the full 3.2 A rating is about 0.594 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
The core stores roughly 396 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
K-factor 64 means the flux swing is about 1,408 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Within the HCM1A1104 family this is value 16 of 19, in a range that runs from 0.2 uH to 100 uH.
One step down the table, HCM1A1104-150-R, sits at 15 uH with 3.8 A and 45 mOhm – the lower inductance buys about 1 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 65 mOhm becomes roughly 99.5 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
Why do V2 and V3 parts exist?
They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd