Eaton HCM1A1104-220-R 22 uH Automotive Power Inductor
Eaton HCM1A1104-220-R 22 uH Automotive Power Inductor

Eaton HCM1A1104-220-R 22 uH Automotive Power Inductor

Share
Eaton HCM1A1104-220-R: AEC-Q200 automotive power inductor, 22 uH ±20%, 3.2 A Irms, Isat 6 A, DCR 58 mOhm, 11.5 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1A1104-220-R 22 uH Automotive Power Inductor

    HCM1A1104-220-R at a glance: AEC-Q200 automotive power inductor, 22 uH ±20%, 3.2 A Irms, Isat 6 A (20% rolloff @ +25 °C), DCR 58 mOhm, 11.5 x 10.3 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1A1104-220-R
    OCL (open circuit inductance)22 uH ±20%
    FLL minimum, at Isat14.1 uH
    Irms (DC, 40 °C rise)3.2 A
    Isat (20% rolloff @ +25 °C)6 A
    DCR typical @ +20 °C58 mOhm
    DCR maximum @ +20 °C65 mOhm
    K-factor (Bp-p = K x L x dI)64, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10550

    Mechanical Drawing

    HCM1A1104-220-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10550: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.

    With 58 mOhm typical, the I-squared-R loss at the full 3.2 A rating is about 0.594 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    The core stores roughly 396 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    K-factor 64 means the flux swing is about 1,408 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Series Positioning

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Within the HCM1A1104 family this is value 16 of 19, in a range that runs from 0.2 uH to 100 uH.

    One step down the table, HCM1A1104-150-R, sits at 15 uH with 3.8 A and 45 mOhm – the lower inductance buys about 1 A of extra current in the same body.

    • Core material: alloy powder core, 11.5 x 10.3 mm body at 4.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Putting It to Work

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 65 mOhm becomes roughly 99.5 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check the hot-corner saturation margin against the worst-case load step.
    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Confirm the qualification file covers the module-level test plan.

    Frequently Asked Questions

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    Why do V2 and V3 parts exist?
    They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products