| Parameter | Value |
|---|---|
| Orderable part number | HCM1A1104-330-R |
| OCL (open circuit inductance) | 33 uH ±20% |
| FLL minimum, at Isat | 21.1 uH |
| Irms (DC, 40 °C rise) | 2.8 A |
| Isat (20% rolloff @ +25 °C) | 4.8 A |
| DCR typical @ +20 °C | 92 mOhm |
| DCR maximum @ +20 °C | 105 mOhm |
| K-factor (Bp-p = K x L x dI) | 44, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 4.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10550 |

Drawing reproduced from Eaton Technical Data 10550: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.
Copper loss at the rated current works out to roughly 0.721 W from a typical DCR of 92 mOhm at 2.8 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
At Isat the part holds about 380 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
With K = 44, a peak-to-peak ripple of one amp produces roughly 1,452 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Within the HCM1A1104 family this is value 17 of 19, in a range that runs from 0.2 uH to 100 uH.
One step down the table, HCM1A1104-220-R, sits at 22 uH with 3.2 A and 58 mOhm – the lower inductance buys about 1.3 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 105 mOhm becomes roughly 161 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
What does AEC-Q200 cover?
The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd