Eaton HCM1A1104V2-1R5-R 1.5 uH AEC-Q200 Inductor, 14 A
Eaton HCM1A1104V2-1R5-R 1.5 uH AEC-Q200 Inductor, 14 A

Eaton HCM1A1104V2-1R5-R 1.5 uH AEC-Q200 Inductor, 14 A

Share
Eaton HCM1A1104V2-1R5-R: AEC-Q200 automotive power inductor, 1.5 uH ±20%, 14 A Irms, Isat 22 A, DCR 3.8 mOhm, 11.2 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1A1104V2-1R5-R 1.5 uH AEC-Q200 Inductor, 14 A

    HCM1A1104V2-1R5-R at a glance: AEC-Q200 automotive power inductor, 1.5 uH ±20%, 14 A Irms, Isat 22 A (20% rolloff @ +25 °C), DCR 3.8 mOhm, 11.2 x 10.3 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1A1104V2-1R5-R
    OCL (open circuit inductance)1.5 uH ±20%
    FLL minimum, at Isat0.96 uH
    Irms (DC, 40 °C rise)14 A
    Isat (20% rolloff @ +25 °C)22 A
    DCR typical @ +20 °C3.8 mOhm
    DCR maximum @ +20 °C4.2 mOhm
    SRF typical33 MHz
    K-factor (Bp-p = K x L x dI)281, Bp-p in Gauss
    Package11.2 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10903

    Mechanical Dimensions & Pad Layout

    HCM1A1104V2-1R5-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10903: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    With 3.8 mOhm typical, the I-squared-R loss at the full 14 A rating is about 0.745 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    Stored energy at Isat is about 363 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    The K-factor of 281 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 422 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Self-resonant frequency is 33 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Series Positioning

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Within the HCM1A1104V2 family this is value 8 of 19, in a range that runs from 0.2 uH to 68 uH.

    One step down the table, HCM1A1104V2-1R0-R, sits at 1.0 uH with 19 A and 2.7 mOhm – the lower inductance buys about 8.5 A of extra current in the same body.

    • Core material: alloy powder core, 11.2 x 10.3 mm body at 4.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 4.2 mOhm becomes roughly 6.43 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Check the hot-corner saturation margin against the worst-case load step.
    • Confirm the qualification file covers the module-level test plan.

    Frequently Asked Questions

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.

    What does AEC-Q200 cover?
    The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.