| Parameter | Value |
|---|---|
| Orderable part number | HCM1A1104V2-5R6-R |
| OCL (open circuit inductance) | 5.6 uH ±20% |
| FLL minimum, at Isat | 3.58 uH |
| Irms (DC, 40 °C rise) | 7.5 A |
| Isat (20% rolloff @ +25 °C) | 9 A |
| DCR typical @ +20 °C | 14 mOhm |
| DCR maximum @ +20 °C | 17 mOhm |
| SRF typical | 14 MHz |
| K-factor (Bp-p = K x L x dI) | 160, Bp-p in Gauss |
| Package | 11.2 x 10.3 mm |
| Height | 4.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10903 |

Drawing reproduced from Eaton Technical Data 10903: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.
The DCR figure of 14 mOhm is what sets the efficiency: at 7.5 A the winding drops about 0.105 mV and dissipates 0.787 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
The core stores roughly 227 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
K-factor 160 means the flux swing is about 896 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
Self-resonant frequency is 14 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Of the 19 values listed for HCM1A1104V2, this is the 12th, in a family covering 0.2 uH to 68 uH.
Compared with its neighbours in the table, HCM1A1104V2-6R8-R trades 1.6 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 17 mOhm becomes roughly 26 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.
Why do V2 and V3 parts exist?
They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd