| Parameter | Value |
|---|---|
| Orderable part number | HCM1A1104V2-R20-R |
| OCL (open circuit inductance) | 0.20 uH ±20% |
| FLL minimum, at Isat | 0.13 uH |
| Irms (DC, 40 °C rise) | 43 A |
| Isat (20% rolloff @ +25 °C) | 60 A |
| DCR typical @ +20 °C | 0.63 mOhm |
| DCR maximum @ +20 °C | 0.72 mOhm |
| SRF typical | 150 MHz |
| K-factor (Bp-p = K x L x dI) | 726, Bp-p in Gauss |
| Package | 11.2 x 10.3 mm |
| Height | 4.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10903 |

Drawing reproduced from Eaton Technical Data 10903: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.
Copper loss at the rated current works out to roughly 1.17 W from a typical DCR of 0.63 mOhm at 43 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
At Isat the part holds about 360 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
The K-factor of 726 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 145 Gauss of Bp-p, the figure the core-loss curve is plotted against.
Self-resonant frequency is 150 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Within the HCM1A1104V2 family this is value 1 of 19, in a range that runs from 0.2 uH to 68 uH.
The next value up in the same family, HCM1A1104V2-R36-R, gives 0.36 uH at 26 A and DCR 1.04 mOhm: the extra inductance costs about 0 A of rated current.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 0.72 mOhm becomes roughly 1.1 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Why do V2 and V3 parts exist?
They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.
What does AEC-Q200 cover?
The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.
Why do V2 and V3 parts exist?
They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd