Eaton HCM1A1104V2-R45-R 0.45 uH Automotive Power Inductor
Eaton HCM1A1104V2-R45-R 0.45 uH Automotive Power Inductor

Eaton HCM1A1104V2-R45-R 0.45 uH Automotive Power Inductor

Share
Eaton HCM1A1104V2-R45-R: AEC-Q200 automotive power inductor, 0.45 uH ±20%, 25 A Irms, Isat 40 A, DCR 1.07 mOhm, 11.2 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1A1104V2-R45-R 0.45 uH Automotive Power Inductor

    HCM1A1104V2-R45-R at a glance: AEC-Q200 automotive power inductor, 0.45 uH ±20%, 25 A Irms, Isat 40 A (20% rolloff @ +25 °C), DCR 1.07 mOhm, 11.2 x 10.3 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1A1104V2-R45-R
    OCL (open circuit inductance)0.45 uH ±20%
    FLL minimum, at Isat0.29 uH
    Irms (DC, 40 °C rise)25 A
    Isat (20% rolloff @ +25 °C)40 A
    DCR typical @ +20 °C1.07 mOhm
    DCR maximum @ +20 °C1.23 mOhm
    SRF typical85 MHz
    K-factor (Bp-p = K x L x dI)450, Bp-p in Gauss
    Package11.2 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10903

    Dimensions and Pad Layout

    HCM1A1104V2-R45-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10903: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    The DCR figure of 1.07 mOhm is what sets the efficiency: at 25 A the winding drops about 0.027 mV and dissipates 0.669 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    At Isat the part holds about 360 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    K-factor 450 means the flux swing is about 202 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Self-resonant frequency is 85 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Positioning in the Range

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Of the 19 values listed for HCM1A1104V2, this is the 3th, in a family covering 0.2 uH to 68 uH.

    The next value up in the same family, HCM1A1104V2-R47-R, gives 0.47 uH at 25 A and DCR 1.1 mOhm: the extra inductance costs about 1 A of rated current.

    • Core material: alloy powder core, 11.2 x 10.3 mm body at 4.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 1.23 mOhm becomes roughly 1.88 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Verify the qualification and the mounting process match the assembly line.
    • Verify the qualification and the mounting process match the assembly line.

    Frequently Asked Questions

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products