Eaton HCM1A1104V3-100-R 10 uH Automotive Power Inductor
Eaton HCM1A1104V3-100-R 10 uH Automotive Power Inductor

Eaton HCM1A1104V3-100-R 10 uH Automotive Power Inductor

Share
Eaton HCM1A1104V3-100-R: AEC-Q200 automotive power inductor, 10 uH ±20%, 6 A Irms, Isat 6 A, DCR 27 mOhm, 11.2 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1A1104V3-100-R 10 uH Automotive Power Inductor

    HCM1A1104V3-100-R at a glance: AEC-Q200 automotive power inductor, 10 uH ±20%, 6 A Irms, Isat 6 A (20% rolloff @ +25 °C), DCR 27 mOhm, 11.2 x 10.3 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1A1104V3-100-R
    OCL (open circuit inductance)10 uH ±20%
    FLL minimum, at Isat6.4 uH
    Irms (DC, 40 °C rise)6 A
    Isat (20% rolloff @ +25 °C)6 A
    DCR typical @ +20 °C27 mOhm
    DCR maximum @ +20 °C30 mOhm
    SRF typical10 MHz
    K-factor (Bp-p = K x L x dI)96, Bp-p in Gauss
    Package11.2 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1490

    Dimensions and Pad Layout

    HCM1A1104V3-100-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1490: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    This is the automotive version of the molded high-current inductor. The body is a molded powder core, the winding is shielded by the magnetic material itself, and the operating range runs to +155 °C. It is the part that goes on the DC-DC stages of body electronics, ADAS modules and infotainment head units.

    At the rated 6 A the winding dissipates about 0.972 W in copper alone, using the typical DCR of 27 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Energy storage at the saturation current is around 180 uJ, the number that connects the inductance and the current rating into a single transient figure.

    With K = 96, a peak-to-peak ripple of one amp produces roughly 960 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 10 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    What This Family Is For

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    The HCM1A1104V3 family spans 0.2 uH to 68 uH; this row sits at position 14 of 19.

    Compared with its neighbours in the table, HCM1A1104V3-150-R trades 1.7 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: alloy powder core, 11.2 x 10.3 mm body at 4.0 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 30 mOhm becomes roughly 45.9 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.
    • Check the hot-corner saturation margin against the worst-case load step.

    Frequently Asked Questions

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.