Eaton HCM1A1104V3-220-R 22 uH Shielded Automotive Inductor
Eaton HCM1A1104V3-220-R 22 uH Shielded Automotive Inductor

Eaton HCM1A1104V3-220-R 22 uH Shielded Automotive Inductor

Share
Eaton HCM1A1104V3-220-R: AEC-Q200 automotive power inductor, 22 uH ±20%, 3.8 A Irms, Isat 4.6 A, DCR 58 mOhm, 11.2 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1A1104V3-220-R 22 uH Shielded Automotive Inductor

    HCM1A1104V3-220-R at a glance: AEC-Q200 automotive power inductor, 22 uH ±20%, 3.8 A Irms, Isat 4.6 A (20% rolloff @ +25 °C), DCR 58 mOhm, 11.2 x 10.3 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1A1104V3-220-R
    OCL (open circuit inductance)22 uH ±20%
    FLL minimum, at Isat14.1 uH
    Irms (DC, 40 °C rise)3.8 A
    Isat (20% rolloff @ +25 °C)4.6 A
    DCR typical @ +20 °C58 mOhm
    DCR maximum @ +20 °C65 mOhm
    SRF typical6.5 MHz
    K-factor (Bp-p = K x L x dI)62, Bp-p in Gauss
    Package11.2 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1490

    Mechanical Dimensions & Pad Layout

    HCM1A1104V3-220-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1490: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    The DCR figure of 58 mOhm is what sets the efficiency: at 3.8 A the winding drops about 0.22 mV and dissipates 0.838 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    The core stores roughly 233 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    With K = 62, a peak-to-peak ripple of one amp produces roughly 1,364 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 6.5 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Positioning in the Range

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Within the HCM1A1104V3 family this is value 16 of 19, in a range that runs from 0.2 uH to 68 uH.

    Compared with its neighbours in the table, HCM1A1104V3-330-R trades 1.4 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: alloy powder core, 11.2 x 10.3 mm body at 4.0 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 65 mOhm becomes roughly 99.5 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Verify the qualification and the mounting process match the assembly line.
    • Confirm the qualification file covers the module-level test plan.
    • Verify the qualification and the mounting process match the assembly line.

    Frequently Asked Questions

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products