Eaton HCM1A1105V2-150-R 15 uH Shielded Automotive Inductor
Eaton HCM1A1105V2-150-R 15 uH Shielded Automotive Inductor

Eaton HCM1A1105V2-150-R 15 uH Shielded Automotive Inductor

Share
Eaton HCM1A1105V2-150-R: AEC-Q200 automotive power inductor, 15 uH ±20%, 4.7 A Irms, Isat 7 A, DCR 34.7 mOhm, 11.2 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1A1105V2-150-R 15 uH Shielded Automotive Inductor

    HCM1A1105V2-150-R at a glance: AEC-Q200 automotive power inductor, 15 uH ±20%, 4.7 A Irms, Isat 7 A (20% rolloff @ +25 °C), DCR 34.7 mOhm, 11.2 x 10.3 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1A1105V2-150-R
    OCL (open circuit inductance)15 uH ±20%
    FLL minimum, at Isat9.6 uH
    Irms (DC, 40 °C rise)4.7 A
    Isat (20% rolloff @ +25 °C)7 A
    DCR typical @ +20 °C34.7 mOhm
    DCR maximum @ +20 °C40.3 mOhm
    SRF typical7 MHz
    K-factor (Bp-p = K x L x dI)65, Bp-p in Gauss
    Package11.2 x 10.3 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10909

    Mechanical Drawing

    HCM1A1105V2-150-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10909: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    This is the automotive version of the molded high-current inductor. The body is a molded powder core, the winding is shielded by the magnetic material itself, and the operating range runs to +155 °C. It is the part that goes on the DC-DC stages of body electronics, ADAS modules and infotainment head units.

    At the rated 4.7 A the winding dissipates about 0.767 W in copper alone, using the typical DCR of 34.7 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    Stored energy at Isat is about 368 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    With K = 65, a peak-to-peak ripple of one amp produces roughly 975 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 7 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Where This Series Fits

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Of the 19 values listed for HCM1A1105V2, this is the 15th, in a family covering 0.68 uH to 68 uH.

    One step down the table, HCM1A1105V2-120-R, sits at 12 uH with 5 A and 31.2 mOhm – the lower inductance buys about 1 A of extra current in the same body.

    • Core material: alloy powder core, 11.2 x 10.3 mm body at 5.0 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 40.3 mOhm becomes roughly 61.7 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.
    • Check Isat and DCR at the hot corner, not at +20 °C.

    Frequently Asked Questions

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.