Eaton HCM1A1105V2-2R8-R AEC-Q200 Inductor 2.8 uH, Isat 18 A
Eaton HCM1A1105V2-2R8-R AEC-Q200 Inductor 2.8 uH, Isat 18 A

Eaton HCM1A1105V2-2R8-R AEC-Q200 Inductor 2.8 uH, Isat 18 A

Share
Eaton HCM1A1105V2-2R8-R: AEC-Q200 automotive power inductor, 2.8 uH ±20%, 12 A Irms, Isat 18 A, DCR 5.2 mOhm, 11.2 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1A1105V2-2R8-R AEC-Q200 Inductor 2.8 uH, Isat 18 A

    HCM1A1105V2-2R8-R at a glance: AEC-Q200 automotive power inductor, 2.8 uH ±20%, 12 A Irms, Isat 18 A (20% rolloff @ +25 °C), DCR 5.2 mOhm, 11.2 x 10.3 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1A1105V2-2R8-R
    OCL (open circuit inductance)2.8 uH ±20%
    FLL minimum, at Isat1.79 uH
    Irms (DC, 40 °C rise)12 A
    Isat (20% rolloff @ +25 °C)18 A
    DCR typical @ +20 °C5.2 mOhm
    DCR maximum @ +20 °C6 mOhm
    SRF typical21 MHz
    K-factor (Bp-p = K x L x dI)122, Bp-p in Gauss
    Package11.2 x 10.3 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10909

    Dimensions and Pad Layout

    HCM1A1105V2-2R8-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10909: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.

    With 5.2 mOhm typical, the I-squared-R loss at the full 12 A rating is about 0.749 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    At Isat the part holds about 454 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    With K = 122, a peak-to-peak ripple of one amp produces roughly 342 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 21 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Series Positioning

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Within the HCM1A1105V2 family this is value 8 of 19, in a range that runs from 0.68 uH to 68 uH.

    One step down the table, HCM1A1105V2-2R2-R, sits at 2.2 uH with 14.5 A and 3.9 mOhm – the lower inductance buys about 5 A of extra current in the same body.

    • Core material: alloy powder core, 11.2 x 10.3 mm body at 5.0 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 6 mOhm becomes roughly 9.18 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Verify the qualification and the mounting process match the assembly line.
    • Verify the qualification and the mounting process match the assembly line.
    • Check Isat and DCR at the hot corner, not at +20 °C.

    Frequently Asked Questions

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products