| Parameter | Value |
|---|---|
| Orderable part number | HCM1A1305-4R7-R |
| OCL (open circuit inductance) | 4.7 uH ±20% |
| FLL minimum, at Isat | 3.01 uH |
| Irms (DC, 40 °C rise) | 9.3 A |
| Isat (20% rolloff @ +25 °C) | 15 A |
| DCR typical @ +20 °C | 11 mOhm |
| DCR maximum @ +20 °C | 12.7 mOhm |
| K-factor (Bp-p = K x L x dI) | 102, Bp-p in Gauss |
| Package | 13.8 x 12.5 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10551 |

Drawing reproduced from Eaton Technical Data 10551: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is the automotive version of the molded high-current inductor. The body is a molded powder core, the winding is shielded by the magnetic material itself, and the operating range runs to +155 °C. It is the part that goes on the DC-DC stages of body electronics, ADAS modules and infotainment head units.
The DCR figure of 11 mOhm is what sets the efficiency: at 9.3 A the winding drops about 0.102 mV and dissipates 0.951 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
At Isat the part holds about 529 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
The K-factor of 102 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 479 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
In the HCM1A1305 line-up this part is number 13 of 23 by inductance, between 0.1 uH and 33 uH.
One step down the table, HCM1A1305-3R3-R, sits at 3.3 uH with 12 A and 7.7 mOhm – the lower inductance buys about 3.2 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 12.7 mOhm becomes roughly 19.4 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.
Why do V2 and V3 parts exist?
They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd