Eaton HCM1A1305-R56-R: AEC-Q200 automotive power inductor, 0.56 uH ±20%, 28 A Irms, Isat 36 A, DCR 1.15 mOhm, 13.8 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCM1A1305-R56-R 0.56 uH AEC-Q200 Inductor, 28 A

    HCM1A1305-R56-R at a glance: AEC-Q200 automotive power inductor, 0.56 uH ±20%, 28 A Irms, Isat 36 A (20% rolloff @ +25 °C), DCR 1.15 mOhm, 13.8 x 12.5 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1A1305-R56-R
    OCL (open circuit inductance)0.56 uH ±20%
    FLL minimum, at Isat0.36 uH
    Irms (DC, 40 °C rise)28 A
    Isat (20% rolloff @ +25 °C)36 A
    DCR typical @ +20 °C1.15 mOhm
    DCR maximum @ +20 °C1.33 mOhm
    K-factor (Bp-p = K x L x dI)265, Bp-p in Gauss
    Package13.8 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10551

    Dimensions and Pad Layout

    HCM1A1305-R56-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10551: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    Copper loss at the rated current works out to roughly 0.902 W from a typical DCR of 1.15 mOhm at 28 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    At Isat the part holds about 363 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    The K-factor of 265 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 148 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    What This Family Is For

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Of the 23 values listed for HCM1A1305, this is the 5th, in a family covering 0.1 uH to 33 uH.

    One step down the table, HCM1A1305-R47-R, sits at 0.47 uH with 33 A and 0.8 mOhm – the lower inductance buys about 6 A of extra current in the same body.

    • Core material: alloy powder core, 13.8 x 12.5 mm body at 5.0 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 1.33 mOhm becomes roughly 2.04 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.
    • Verify the qualification and the mounting process match the assembly line.

    Frequently Asked Questions

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What does AEC-Q200 cover?
    The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.

    Why do V2 and V3 parts exist?
    They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.