| Parameter | Value |
|---|---|
| Orderable part number | HCM1A1305V2-4R7-R |
| OCL (open circuit inductance) | 4.7 uH ±20% |
| FLL minimum, at Isat | 3.01 uH |
| Irms (DC, 40 °C rise) | 11 A |
| Isat (20% rolloff @ +25 °C) | 18 A |
| DCR typical @ +20 °C | 8.15 mOhm |
| DCR maximum @ +20 °C | 9.38 mOhm |
| SRF typical | 13 MHz |
| K-factor (Bp-p = K x L x dI) | 93, Bp-p in Gauss |
| Package | 13.8 x 12.9 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10904 |

Drawing reproduced from Eaton Technical Data 10904: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.
Copper loss at the rated current works out to roughly 0.986 W from a typical DCR of 8.15 mOhm at 11 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
At Isat the part holds about 761 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
With K = 93, a peak-to-peak ripple of one amp produces roughly 437 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
Self-resonant frequency is 13 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Of the 23 values listed for HCM1A1305V2, this is the 13th, in a family covering 0.1 uH to 33 uH.
The next value up in the same family, HCM1A1305V2-5R6-R, gives 5.6 uH at 10 A and DCR 11 mOhm: the extra inductance costs about 2 A of rated current.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 9.38 mOhm becomes roughly 14.4 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.
What is the operating temperature range?
The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd