| Parameter | Value |
|---|---|
| Orderable part number | HCM1A1307-150-R |
| OCL (open circuit inductance) | 15 uH ±20% |
| FLL minimum, at Isat | 9.6 uH |
| Irms (DC, 40 °C rise) | 5.5 A |
| Isat (20% rolloff @ +25 °C) | 10 A |
| DCR typical @ +20 °C | 22 mOhm |
| DCR maximum @ +20 °C | 25 mOhm |
| K-factor (Bp-p = K x L x dI) | 36, Bp-p in Gauss |
| Package | 13.7 x 13 mm |
| Height | 6.5 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10552 |

Drawing reproduced from Eaton Technical Data 10552: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.
With 22 mOhm typical, the I-squared-R loss at the full 5.5 A rating is about 0.665 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
The core stores roughly 750 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
With K = 36, a peak-to-peak ripple of one amp produces roughly 540 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Within the HCM1A1307 family this is value 17 of 20, in a range that runs from 0.22 uH to 56 uH.
One step down the table, HCM1A1307-120-R, sits at 12 uH with 6.1 A and 17 mOhm – the lower inductance buys about 1.3 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 25 mOhm becomes roughly 38.3 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
What is the operating temperature range?
The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd