Eaton HCM1A1307-1R0-R 1.0 uH Shielded Automotive Inductor
Eaton HCM1A1307-1R0-R 1.0 uH Shielded Automotive Inductor

Eaton HCM1A1307-1R0-R 1.0 uH Shielded Automotive Inductor

Share
Eaton HCM1A1307-1R0-R: AEC-Q200 automotive power inductor, 1.0 uH ±20%, 28 A Irms, Isat 30 A, DCR 1.65 mOhm, 13.7 x 13 mm.
    • Product Details
    • Download

    Eaton HCM1A1307-1R0-R 1.0 uH Shielded Automotive Inductor

    HCM1A1307-1R0-R at a glance: AEC-Q200 automotive power inductor, 1.0 uH ±20%, 28 A Irms, Isat 30 A (20% rolloff @ +25 °C), DCR 1.65 mOhm, 13.7 x 13 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1A1307-1R0-R
    OCL (open circuit inductance)1.0 uH ±20%
    FLL minimum, at Isat0.64 uH
    Irms (DC, 40 °C rise)28 A
    Isat (20% rolloff @ +25 °C)30 A
    DCR typical @ +20 °C1.65 mOhm
    DCR maximum @ +20 °C1.77 mOhm
    K-factor (Bp-p = K x L x dI)139, Bp-p in Gauss
    Package13.7 x 13 mm
    Height6.5 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10552

    Mechanical Dimensions & Pad Layout

    HCM1A1307-1R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10552: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    This is the automotive version of the molded high-current inductor. The body is a molded powder core, the winding is shielded by the magnetic material itself, and the operating range runs to +155 °C. It is the part that goes on the DC-DC stages of body electronics, ADAS modules and infotainment head units.

    With 1.65 mOhm typical, the I-squared-R loss at the full 28 A rating is about 1.29 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Stored energy at Isat is about 450 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    K-factor 139 means the flux swing is about 139 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Positioning in the Range

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Within the HCM1A1307 family this is value 4 of 20, in a range that runs from 0.22 uH to 56 uH.

    The next value up in the same family, HCM1A1307-1R2-R, gives 1.2 uH at 21.8 A and DCR 1.98 mOhm: the extra inductance costs about 14.7 A of rated current.

    • Core material: alloy powder core, 13.7 x 13 mm body at 6.5 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 1.77 mOhm becomes roughly 2.71 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check the hot-corner saturation margin against the worst-case load step.
    • Verify the part marking for revision traceability in production.
    • Verify the qualification and the mounting process match the assembly line.

    Frequently Asked Questions

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Why do V2 and V3 parts exist?
    They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.