Eaton HCM1A1307-220-R 22 uH Automotive Power Inductor
Eaton HCM1A1307-220-R 22 uH Automotive Power Inductor

Eaton HCM1A1307-220-R 22 uH Automotive Power Inductor

Share
Eaton HCM1A1307-220-R: AEC-Q200 automotive power inductor, 22 uH ±20%, 4.8 A Irms, Isat 8 A, DCR 31.3 mOhm, 13.7 x 13 mm.
    • Product Details
    • Download

    Eaton HCM1A1307-220-R 22 uH Automotive Power Inductor

    HCM1A1307-220-R at a glance: AEC-Q200 automotive power inductor, 22 uH ±20%, 4.8 A Irms, Isat 8 A (20% rolloff @ +25 °C), DCR 31.3 mOhm, 13.7 x 13 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1A1307-220-R
    OCL (open circuit inductance)22 uH ±20%
    FLL minimum, at Isat14.1 uH
    Irms (DC, 40 °C rise)4.8 A
    Isat (20% rolloff @ +25 °C)8 A
    DCR typical @ +20 °C31.3 mOhm
    DCR maximum @ +20 °C35 mOhm
    K-factor (Bp-p = K x L x dI)29, Bp-p in Gauss
    Package13.7 x 13 mm
    Height6.5 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10552

    Mechanical Drawing

    HCM1A1307-220-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10552: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    Copper loss at the rated current works out to roughly 0.721 W from a typical DCR of 31.3 mOhm at 4.8 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Stored energy at Isat is about 704 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    With K = 29, a peak-to-peak ripple of one amp produces roughly 638 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    What This Family Is For

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Within the HCM1A1307 family this is value 18 of 20, in a range that runs from 0.22 uH to 56 uH.

    One step down the table, HCM1A1307-150-R, sits at 15 uH with 5.5 A and 22 mOhm – the lower inductance buys about 0.8 A of extra current in the same body.

    • Core material: alloy powder core, 13.7 x 13 mm body at 6.5 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 35 mOhm becomes roughly 53.6 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Check Isat and DCR at the hot corner, not at +20 °C.

    Frequently Asked Questions

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products