| Parameter | Value |
|---|---|
| Orderable part number | HCM1A1307-3R3-R |
| OCL (open circuit inductance) | 3.3 uH ±20% |
| FLL minimum, at Isat | 2.11 uH |
| Irms (DC, 40 °C rise) | 15.6 A |
| Isat (20% rolloff @ +25 °C) | 20 A |
| DCR typical @ +20 °C | 3.7 mOhm |
| DCR maximum @ +20 °C | 4.3 mOhm |
| K-factor (Bp-p = K x L x dI) | 99, Bp-p in Gauss |
| Package | 13.7 x 13 mm |
| Height | 6.5 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10552 |

Drawing reproduced from Eaton Technical Data 10552: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.
At the rated 15.6 A the winding dissipates about 0.9 W in copper alone, using the typical DCR of 3.7 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
At Isat the part holds about 660 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
With K = 99, a peak-to-peak ripple of one amp produces roughly 327 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
In the HCM1A1307 line-up this part is number 9 of 20 by inductance, between 0.22 uH and 56 uH.
Compared with its neighbours in the table, HCM1A1307-4R7-R trades 6.6 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 4.3 mOhm becomes roughly 6.58 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What does AEC-Q200 cover?
The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.
What is the operating temperature range?
The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd