| Parameter | Value |
|---|---|
| Orderable part number | HCM1A1307-5R6-R |
| OCL (open circuit inductance) | 5.6 uH ±20% |
| FLL minimum, at Isat | 3.58 uH |
| Irms (DC, 40 °C rise) | 10 A |
| Isat (20% rolloff @ +25 °C) | 17 A |
| DCR typical @ +20 °C | 7.5 mOhm |
| DCR maximum @ +20 °C | 9 mOhm |
| K-factor (Bp-p = K x L x dI) | 65, Bp-p in Gauss |
| Package | 13.7 x 13 mm |
| Height | 6.5 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10552 |

Drawing reproduced from Eaton Technical Data 10552: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is the automotive version of the molded high-current inductor. The body is a molded powder core, the winding is shielded by the magnetic material itself, and the operating range runs to +155 °C. It is the part that goes on the DC-DC stages of body electronics, ADAS modules and infotainment head units.
At the rated 10 A the winding dissipates about 0.75 W in copper alone, using the typical DCR of 7.5 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
The core stores roughly 809 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
K-factor 65 means the flux swing is about 364 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
The HCM1A1307 family spans 0.22 uH to 56 uH; this row sits at position 11 of 20.
The next value up in the same family, HCM1A1307-6R8-R, gives 6.8 uH at 9 A and DCR 10 mOhm: the extra inductance costs about 2 A of rated current.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 9 mOhm becomes roughly 13.8 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
What does AEC-Q200 cover?
The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd