
| Parameter | Value |
|---|---|
| Orderable part number | HCM1A1307-7R8-R |
| OCL (open circuit inductance) | 7.8 uH ±20% |
| FLL minimum, at Isat | 4.99 uH |
| Irms (DC, 40 °C rise) | 8.8 A |
| Isat (20% rolloff @ +25 °C) | 16 A |
| DCR typical @ +20 °C | 10 mOhm |
| DCR maximum @ +20 °C | 11.5 mOhm |
| K-factor (Bp-p = K x L x dI) | 52, Bp-p in Gauss |
| Package | 13.7 x 13 mm |
| Height | 6.5 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10552 |

Drawing reproduced from Eaton Technical Data 10552: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.
Copper loss at the rated current works out to roughly 0.774 W from a typical DCR of 10 mOhm at 8.8 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
At Isat the part holds about 998 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
K-factor 52 means the flux swing is about 406 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Within the HCM1A1307 family this is value 13 of 20, in a range that runs from 0.22 uH to 56 uH.
The next value up in the same family, HCM1A1307-8R2-R, gives 8.2 uH at 8.2 A and DCR 11.5 mOhm: the extra inductance costs about 0.8 A of rated current.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 11.5 mOhm becomes roughly 17.6 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Why do V2 and V3 parts exist?
They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd