| Parameter | Value |
|---|---|
| Orderable part number | HCM1A1307V2-1R5-R |
| OCL (open circuit inductance) | 1.5 uH ±20% |
| FLL minimum, at Isat | 0.96 uH |
| Irms (DC, 40 °C rise) | 21 A |
| Isat (20% rolloff @ +25 °C) | 25 A |
| DCR typical @ +20 °C | 2.04 mOhm |
| DCR maximum @ +20 °C | 2.4 mOhm |
| SRF typical | 31 MHz |
| K-factor (Bp-p = K x L x dI) | 126, Bp-p in Gauss |
| Package | 13.8 x 12.9 mm |
| Height | 6.5 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10905 |

Drawing reproduced from Eaton Technical Data 10905: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.
With 2.04 mOhm typical, the I-squared-R loss at the full 21 A rating is about 0.9 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
At Isat the part holds about 469 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
The K-factor of 126 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 189 Gauss of Bp-p, the figure the core-loss curve is plotted against.
Self-resonant frequency is 31 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Within the HCM1A1307V2 family this is value 6 of 20, in a range that runs from 0.22 uH to 56 uH.
One step down the table, HCM1A1307V2-1R2-R, sits at 1.2 uH with 22.5 A and 1.78 mOhm – the lower inductance buys about 3.5 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 2.4 mOhm becomes roughly 3.67 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.
Why do V2 and V3 parts exist?
They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.
Why do V2 and V3 parts exist?
They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.