Eaton HCM1A1307V2-220-R 22 uH Automotive Power Inductor
Eaton HCM1A1307V2-220-R 22 uH Automotive Power Inductor

Eaton HCM1A1307V2-220-R 22 uH Automotive Power Inductor

Share
Eaton HCM1A1307V2-220-R: AEC-Q200 automotive power inductor, 22 uH ±20%, 6 A Irms, Isat 8 A, DCR 28.8 mOhm, 13.8 x 12.9 mm.
    • Product Details
    • Download

    Eaton HCM1A1307V2-220-R 22 uH Automotive Power Inductor

    HCM1A1307V2-220-R at a glance: AEC-Q200 automotive power inductor, 22 uH ±20%, 6 A Irms, Isat 8 A (20% rolloff @ +25 °C), DCR 28.8 mOhm, 13.8 x 12.9 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1A1307V2-220-R
    OCL (open circuit inductance)22 uH ±20%
    FLL minimum, at Isat14.1 uH
    Irms (DC, 40 °C rise)6 A
    Isat (20% rolloff @ +25 °C)8 A
    DCR typical @ +20 °C28.8 mOhm
    DCR maximum @ +20 °C33.1 mOhm
    SRF typical5 MHz
    K-factor (Bp-p = K x L x dI)28, Bp-p in Gauss
    Package13.8 x 12.9 mm
    Height6.5 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10905

    Mechanical Dimensions & Pad Layout

    HCM1A1307V2-220-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10905: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.

    With 28.8 mOhm typical, the I-squared-R loss at the full 6 A rating is about 1.04 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    The core stores roughly 704 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    The K-factor of 28 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 616 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Self-resonant frequency is 5 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Positioning in the Range

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Within the HCM1A1307V2 family this is value 18 of 20, in a range that runs from 0.22 uH to 56 uH.

    One step down the table, HCM1A1307V2-150-R, sits at 15 uH with 7 A and 20.3 mOhm – the lower inductance buys about 2 A of extra current in the same body.

    • Core material: alloy powder core, 13.8 x 12.9 mm body at 6.5 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Putting It to Work

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 33.1 mOhm becomes roughly 50.7 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Confirm the qualification file covers the module-level test plan.
    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Check Isat and DCR at the hot corner, not at +20 °C.

    Frequently Asked Questions

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.

    What does AEC-Q200 cover?
    The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.