| Parameter | Value |
|---|---|
| Orderable part number | HCM1A1307V2-4R7-R |
| OCL (open circuit inductance) | 4.7 uH ±20% |
| FLL minimum, at Isat | 3 uH |
| Irms (DC, 40 °C rise) | 13 A |
| Isat (20% rolloff @ +25 °C) | 20 A |
| DCR typical @ +20 °C | 6.25 mOhm |
| DCR maximum @ +20 °C | 7.25 mOhm |
| SRF typical | 14 MHz |
| K-factor (Bp-p = K x L x dI) | 71, Bp-p in Gauss |
| Package | 13.8 x 12.9 mm |
| Height | 6.5 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10905 |

Drawing reproduced from Eaton Technical Data 10905: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.
Copper loss at the rated current works out to roughly 1.06 W from a typical DCR of 6.25 mOhm at 13 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
Energy storage at the saturation current is around 940 uJ, the number that connects the inductance and the current rating into a single transient figure.
The K-factor of 71 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 334 Gauss of Bp-p, the figure the core-loss curve is plotted against.
Self-resonant frequency is 14 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Within the HCM1A1307V2 family this is value 10 of 20, in a range that runs from 0.22 uH to 56 uH.
Compared with its neighbours in the table, HCM1A1307V2-5R6-R trades 4.5 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 7.25 mOhm becomes roughly 11.1 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Is the part shielded for ADAS modules?
The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.
What does AEC-Q200 cover?
The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.
Why do V2 and V3 parts exist?
They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd