Eaton HCM1A1307V2-560-R: AEC-Q200 automotive power inductor, 56 uH ±20%, 4 A Irms, Isat 4.3 A, DCR 55 mOhm, 13.8 x 12.9 mm.
    • Product Details
    • Download

    Eaton HCM1A1307V2-560-R 56 uH Shielded Automotive Inductor

    HCM1A1307V2-560-R at a glance: AEC-Q200 automotive power inductor, 56 uH ±20%, 4 A Irms, Isat 4.3 A (20% rolloff @ +25 °C), DCR 55 mOhm, 13.8 x 12.9 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1A1307V2-560-R
    OCL (open circuit inductance)56 uH ±20%
    FLL minimum, at Isat35.8 uH
    Irms (DC, 40 °C rise)4 A
    Isat (20% rolloff @ +25 °C)4.3 A
    DCR typical @ +20 °C55 mOhm
    DCR maximum @ +20 °C65 mOhm
    SRF typical2 MHz
    K-factor (Bp-p = K x L x dI)23, Bp-p in Gauss
    Package13.8 x 12.9 mm
    Height6.5 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10905

    Dimensions and Pad Layout

    HCM1A1307V2-560-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10905: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    This is the automotive version of the molded high-current inductor. The body is a molded powder core, the winding is shielded by the magnetic material itself, and the operating range runs to +155 °C. It is the part that goes on the DC-DC stages of body electronics, ADAS modules and infotainment head units.

    With 55 mOhm typical, the I-squared-R loss at the full 4 A rating is about 0.88 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    At Isat the part holds about 518 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    With K = 23, a peak-to-peak ripple of one amp produces roughly 1,288 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 2 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Series Positioning

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    In the HCM1A1307V2 line-up this part is number 20 of 20 by inductance, between 0.22 uH and 56 uH.

    One step down the table, HCM1A1307V2-330-R, sits at 33 uH with 5 A and 40.8 mOhm – the lower inductance buys about 0 A of extra current in the same body.

    • Core material: alloy powder core, 13.8 x 12.9 mm body at 6.5 mm.
    • Typical applications: body electronics; central body control module; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control; advanced driver assistance systems.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 65 mOhm becomes roughly 99.5 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Verify the qualification and the mounting process match the assembly line.
    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Check the hot-corner saturation margin against the worst-case load step.

    Frequently Asked Questions

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Why do V2 and V3 parts exist?
    They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products