| Parameter | Value |
|---|---|
| Orderable part number | HCM1A1707-3R3-R |
| OCL (open circuit inductance) | 3.3 uH ±20% |
| FLL minimum, at Isat | 2.11 uH |
| Irms (DC, 40 °C rise) | 21 A |
| Isat (20% rolloff @ +25 °C) | 22 A |
| DCR typical @ +20 °C | 3.1 mOhm |
| DCR maximum @ +20 °C | 3.4 mOhm |
| K-factor (Bp-p = K x L x dI) | 103, Bp-p in Gauss |
| Package | 17.5 x 17.2 mm |
| Height | 7.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10553 |

Drawing reproduced from Eaton Technical Data 10553: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.
At the rated 21 A the winding dissipates about 1.37 W in copper alone, using the typical DCR of 3.1 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
Stored energy at Isat is about 799 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
K-factor 103 means the flux swing is about 340 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Within the HCM1A1707 family this is value 4 of 13, in a range that runs from 1 uH to 68 uH.
One step down the table, HCM1A1707-2R2-R, sits at 2.2 uH with 24 A and 2.4 mOhm – the lower inductance buys about 6 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 3.4 mOhm becomes roughly 5.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
Shenzhen Gaorunxin Technology Co., Ltd