Eaton HCM1A4020V3-100-R 10 uH Shielded Automotive Inductor
Eaton HCM1A4020V3-100-R 10 uH Shielded Automotive Inductor

Eaton HCM1A4020V3-100-R 10 uH Shielded Automotive Inductor

Share
Eaton HCM1A4020V3-100-R: AEC-Q200 automotive power inductor, 10 uH ±20%, 1.6 A Irms, Isat 2.2 A, DCR 245 mOhm, 4.75 x 4.45 mm.
    • Product Details
    • Download

    Eaton HCM1A4020V3-100-R 10 uH Shielded Automotive Inductor

    HCM1A4020V3-100-R at a glance: AEC-Q200 automotive power inductor, 10 uH ±20%, 1.6 A Irms, Isat 2.2 A (20% rolloff @ +25 °C), DCR 245 mOhm, 4.75 x 4.45 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1A4020V3-100-R
    OCL (open circuit inductance)10 uH ±20%
    FLL minimum, at Isat5.6 uH
    Irms (DC, 40 °C rise)1.6 A
    Isat (20% rolloff @ +25 °C)2.2 A
    DCR typical @ +20 °C245 mOhm
    DCR maximum @ +20 °C281 mOhm
    SRF typical20 MHz
    K-factor (Bp-p = K x L x dI)363, Bp-p in Gauss
    Package4.75 x 4.45 mm
    Height2.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1495

    Dimensions and Pad Layout

    HCM1A4020V3-100-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1495: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    The DCR figure of 245 mOhm is what sets the efficiency: at 1.6 A the winding drops about 0.392 mV and dissipates 0.627 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    Energy storage at the saturation current is around 24.2 uJ, the number that connects the inductance and the current rating into a single transient figure.

    With K = 363, a peak-to-peak ripple of one amp produces roughly 3,630 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 20 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Series Positioning

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Within the HCM1A4020V3 family this is value 14 of 15, in a range that runs from 0.1 uH to 15 uH.

    Compared with its neighbours in the table, HCM1A4020V3-150-R trades 0.3 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: alloy powder core, 4.75 x 4.45 mm body at 2.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Putting It to Work

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 281 mOhm becomes roughly 430 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Verify the qualification and the mounting process match the assembly line.
    • Confirm the qualification file covers the module-level test plan.
    • Confirm the qualification file covers the module-level test plan.

    Frequently Asked Questions

    What does AEC-Q200 cover?
    The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products