Eaton HCM1A4020V3-3R3-R AEC-Q200 Inductor 3.3 uH, Isat 4 A
Eaton HCM1A4020V3-3R3-R AEC-Q200 Inductor 3.3 uH, Isat 4 A

Eaton HCM1A4020V3-3R3-R AEC-Q200 Inductor 3.3 uH, Isat 4 A

Share
Eaton HCM1A4020V3-3R3-R: AEC-Q200 automotive power inductor, 3.3 uH ±20%, 3.1 A Irms, Isat 4 A, DCR 71 mOhm, 4.75 x 4.45 mm.
    • Product Details
    • Download

    Eaton HCM1A4020V3-3R3-R AEC-Q200 Inductor 3.3 uH, Isat 4 A

    HCM1A4020V3-3R3-R at a glance: AEC-Q200 automotive power inductor, 3.3 uH ±20%, 3.1 A Irms, Isat 4 A (20% rolloff @ +25 °C), DCR 71 mOhm, 4.75 x 4.45 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1A4020V3-3R3-R
    OCL (open circuit inductance)3.3 uH ±20%
    FLL minimum, at Isat1.85 uH
    Irms (DC, 40 °C rise)3.1 A
    Isat (20% rolloff @ +25 °C)4 A
    DCR typical @ +20 °C71 mOhm
    DCR maximum @ +20 °C85 mOhm
    SRF typical35 MHz
    K-factor (Bp-p = K x L x dI)803, Bp-p in Gauss
    Package4.75 x 4.45 mm
    Height2.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1495

    Dimensions and Pad Layout

    HCM1A4020V3-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1495: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.

    Copper loss at the rated current works out to roughly 0.682 W from a typical DCR of 71 mOhm at 3.1 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Energy storage at the saturation current is around 26.4 uJ, the number that connects the inductance and the current rating into a single transient figure.

    With K = 803, a peak-to-peak ripple of one amp produces roughly 2,650 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Self-resonant frequency is 35 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    What This Family Is For

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Of the 15 values listed for HCM1A4020V3, this is the 11th, in a family covering 0.1 uH to 15 uH.

    One step down the table, HCM1A4020V3-2R2-R, sits at 2.2 uH with 4.6 A and 40 mOhm – the lower inductance buys about 2.1 A of extra current in the same body.

    • Core material: alloy powder core, 4.75 x 4.45 mm body at 2.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 85 mOhm becomes roughly 130 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check the hot-corner saturation margin against the worst-case load step.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.
    • Verify the part marking for revision traceability in production.

    Frequently Asked Questions

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products