| Parameter | Value |
|---|---|
| Orderable part number | HCMA0503-3R3-R |
| OCL (open circuit inductance) | 3.3 uH ±20% |
| FLL minimum, at Isat | 2.1 uH |
| Irms (DC, 40 °C rise) | 5.5 A |
| Isat (20% rolloff @ +25 °C) | 6 A |
| DCR typical @ +20 °C | 36.4 mOhm |
| DCR maximum @ +20 °C | 40.4 mOhm |
| K-factor (Bp-p = K x L x dI) | 273, Bp-p in Gauss |
| Package | 5.5 x 5.3 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10248 |

Drawing reproduced from Eaton Technical Data 10248: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The family takes the molded construction used on the commercial high-current parts and applies the automotive qualification and temperature range. Soft saturation and low DCR are the two properties that matter on a 48 V or 12 V rail carrying tens of amps.
With 36.4 mOhm typical, the I-squared-R loss at the full 5.5 A rating is about 1.1 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
At Isat the part holds about 59.4 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
K-factor 273 means the flux swing is about 901 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.
In the HCMA0503 line-up this part is number 8 of 14 by inductance, between 0.2 uH and 22 uH.
Compared with its neighbours in the table, HCMA0503-4R7-R trades 2.3 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 40.4 mOhm becomes roughly 57.1 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.
Is it shielded?
Yes – the winding is enclosed in the molded powder core, which keeps the external field low enough for dense automotive boards.
Can it be used on a 48 V rail?
The inductance and current ratings suit 48 V converters, but the insulation system and creepage are board-level concerns. Check the terminal spacing and conformal coating against the rail voltage.
What is the difference between Irms and Isat here?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
Shenzhen Gaorunxin Technology Co., Ltd