Eaton HCMA0703-100-R 10 uH Automotive High-Current Inductor
Eaton HCMA0703-100-R 10 uH Automotive High-Current Inductor

Eaton HCMA0703-100-R 10 uH Automotive High-Current Inductor

Share
Eaton HCMA0703-100-R: AEC-Q200 high-current inductor, 10 uH ±20%, 3.2 A Irms, Isat 7 A, DCR 71 mOhm, 7.4 x 7 mm.
    • Product Details
    • Download

    Eaton HCMA0703-100-R 10 uH Automotive High-Current Inductor

    HCMA0703-100-R at a glance: AEC-Q200 high-current inductor, 10 uH ±20%, 3.2 A Irms, Isat 7 A (20% rolloff @ +25 °C), DCR 71 mOhm, 7.4 x 7 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCMA0703-100-R
    OCL (open circuit inductance)10 uH ±20%
    FLL minimum, at Isat6 uH
    Irms (DC, 40 °C rise)3.2 A
    Isat (20% rolloff @ +25 °C)7 A
    DCR typical @ +20 °C71 mOhm
    DCR maximum @ +20 °C78 mOhm
    K-factor (Bp-p = K x L x dI)132, Bp-p in Gauss
    Package7.4 x 7 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10282

    Dimensions and Pad Layout

    HCMA0703-100-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10282: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    The family takes the molded construction used on the commercial high-current parts and applies the automotive qualification and temperature range. Soft saturation and low DCR are the two properties that matter on a 48 V or 12 V rail carrying tens of amps.

    The DCR figure of 71 mOhm is what sets the efficiency: at 3.2 A the winding drops about 0.227 mV and dissipates 0.727 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Energy storage at the saturation current is around 245 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The K-factor of 132 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 1,320 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Positioning in the Range

    The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.

    Within the HCMA0703 family this is value 13 of 15, in a range that runs from 0.15 uH to 33 uH.

    The next value up in the same family, HCMA0703-220-R, gives 22 uH at 2.3 A and DCR 135 mOhm: the extra inductance costs about 1.7 A of rated current.

    • Core material: iron powder core, 7.4 x 7 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tai lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • Automotive derating practice: size against the saturation current at the hot corner and keep margin for the load transient, not just the steady-state current.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 78 mOhm becomes roughly 110 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.

    • Compare against the commercial HCM row of the same size before substituting.
    • Size the saturation margin at the maximum ambient the module will see.
    • Check the terminal spacing against the rail voltage and the coating scheme.

    Frequently Asked Questions

    Is this part suitable for a 48 V rail?
    The electrical ratings suit it, but isolation and creepage are board-level decisions. Check terminal spacing and any coating against the rail voltage.

    What current can it carry continuously?
    The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.

    What current can it carry continuously?
    The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products