| Parameter | Value |
|---|---|
| Orderable part number | HCMA0703-220-R |
| OCL (open circuit inductance) | 22 uH ±20% |
| FLL minimum, at Isat | 14.1 uH |
| Irms (DC, 40 °C rise) | 2.3 A |
| Isat (20% rolloff @ +25 °C) | 3 A |
| DCR typical @ +20 °C | 135 mOhm |
| DCR maximum @ +20 °C | 149 mOhm |
| K-factor (Bp-p = K x L x dI) | 83, Bp-p in Gauss |
| Package | 7.4 x 7 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10282 |

Drawing reproduced from Eaton Technical Data 10282: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The family takes the molded construction used on the commercial high-current parts and applies the automotive qualification and temperature range. Soft saturation and low DCR are the two properties that matter on a 48 V or 12 V rail carrying tens of amps.
At the rated 2.3 A the winding dissipates about 0.714 W in copper alone, using the typical DCR of 135 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
Energy storage at the saturation current is around 99 uJ, the number that connects the inductance and the current rating into a single transient figure.
K-factor 83 means the flux swing is about 1,826 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.
The HCMA0703 family spans 0.15 uH to 33 uH; this row sits at position 14 of 15.
One step down the table, HCMA0703-100-R, sits at 10 uH with 3.2 A and 71 mOhm – the lower inductance buys about 1.4 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 149 mOhm becomes roughly 210 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.
What is the difference between Irms and Isat here?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
Is this part suitable for a 48 V rail?
The electrical ratings suit it, but isolation and creepage are board-level decisions. Check terminal spacing and any coating against the rail voltage.
What is the difference between Irms and Isat here?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd