Eaton HCMA0703-8R2-R AEC-Q200 Inductor 8.2 uH, Isat 7.5 A
Eaton HCMA0703-8R2-R AEC-Q200 Inductor 8.2 uH, Isat 7.5 A

Eaton HCMA0703-8R2-R AEC-Q200 Inductor 8.2 uH, Isat 7.5 A

Share
Eaton HCMA0703-8R2-R: AEC-Q200 high-current inductor, 8.2 uH ±20%, 4 A Irms, Isat 7.5 A, DCR 64 mOhm, 7.4 x 7 mm.
    • Product Details
    • Download

    Eaton HCMA0703-8R2-R AEC-Q200 Inductor 8.2 uH, Isat 7.5 A

    HCMA0703-8R2-R at a glance: AEC-Q200 high-current inductor, 8.2 uH ±20%, 4 A Irms, Isat 7.5 A (20% rolloff @ +25 °C), DCR 64 mOhm, 7.4 x 7 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCMA0703-8R2-R
    OCL (open circuit inductance)8.2 uH ±20%
    FLL minimum, at Isat4.92 uH
    Irms (DC, 40 °C rise)4 A
    Isat (20% rolloff @ +25 °C)7.5 A
    DCR typical @ +20 °C64 mOhm
    DCR maximum @ +20 °C68 mOhm
    K-factor (Bp-p = K x L x dI)142, Bp-p in Gauss
    Package7.4 x 7 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10282

    Mechanical Drawing

    HCMA0703-8R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10282: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    AEC-Q200 qualified high-current inductor on a molded powder core, rated to +125 °C. The construction is chosen for current density: the winding is pressed into the magnetic material, so there is no bobbin wasting window area and the DCR stays low for the body size.

    Copper loss at the rated current works out to roughly 1.02 W from a typical DCR of 64 mOhm at 4 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    The core stores roughly 231 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    With K = 142, a peak-to-peak ripple of one amp produces roughly 1,164 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    What This Family Is For

    The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.

    The HCMA0703 family spans 0.15 uH to 33 uH; this row sits at position 12 of 15.

    Compared with its neighbours in the table, HCMA0703-100-R trades 1.3 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 7.4 x 7 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tai lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • Automotive derating practice: size against the saturation current at the hot corner and keep margin for the load transient, not just the steady-state current.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 68 mOhm becomes roughly 96.1 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.

    • Verify the shielding against the EMC plan for the board.
    • Check the current derating at the maximum ambient of the module.
    • Check the terminal spacing against the rail voltage and the coating scheme.

    Frequently Asked Questions

    What current can it carry continuously?
    The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.

    Is this part suitable for a 48 V rail?
    The electrical ratings suit it, but isolation and creepage are board-level decisions. Check terminal spacing and any coating against the rail voltage.

    Is it shielded?
    Yes – the winding is enclosed in the molded powder core, which keeps the external field low enough for dense automotive boards.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products