| Parameter | Value |
|---|---|
| Orderable part number | HCMA1104-100-R |
| OCL (open circuit inductance) | 10 uH ±20% |
| FLL minimum, at Isat | 5.6 uH |
| Irms (DC, 40 °C rise) | 7.5 A |
| Isat (20% rolloff @ +25 °C) | 8.5 A |
| DCR typical @ +20 °C | 27 mOhm |
| DCR maximum @ +20 °C | 30 mOhm |
| K-factor (Bp-p = K x L x dI) | 116, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 4.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10349 |

Drawing reproduced from Eaton Technical Data 10349: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The family takes the molded construction used on the commercial high-current parts and applies the automotive qualification and temperature range. Soft saturation and low DCR are the two properties that matter on a 48 V or 12 V rail carrying tens of amps.
Copper loss at the rated current works out to roughly 1.52 W from a typical DCR of 27 mOhm at 7.5 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
Energy storage at the saturation current is around 361 uJ, the number that connects the inductance and the current rating into a single transient figure.
The K-factor of 116 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 1,160 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.
The HCMA1104 family spans 0.2 uH to 22 uH; this row sits at position 11 of 12.
Compared with its neighbours in the table, HCMA1104-220-R trades 3.5 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 30 mOhm becomes roughly 42.4 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.
How does this differ from the commercial HCM part?
Same molded construction and similar body sizes, but automotive qualified, characterised to +125 °C, and wound for higher current in the larger sizes. The electrical rows are not interchangeable.
Is this part suitable for a 48 V rail?
The electrical ratings suit it, but isolation and creepage are board-level decisions. Check terminal spacing and any coating against the rail voltage.
What current can it carry continuously?
The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd