| Parameter | Value |
|---|---|
| Orderable part number | HCMA1104-1R0-R |
| OCL (open circuit inductance) | 1.0 uH ±20% |
| FLL minimum, at Isat | 0.56 uH |
| Irms (DC, 40 °C rise) | 18 A |
| Isat (20% rolloff @ +25 °C) | 28 A |
| DCR typical @ +20 °C | 3 mOhm |
| DCR maximum @ +20 °C | 3.3 mOhm |
| K-factor (Bp-p = K x L x dI) | 378, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 4.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10349 |

Drawing reproduced from Eaton Technical Data 10349: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is the high-current member of the automotive molded family. Where the standard automotive parts top out at a few tens of amps, this one is built for the main DC-DC stage: thicker winding, larger body, and a saturation current that scales with it.
The DCR figure of 3 mOhm is what sets the efficiency: at 18 A the winding drops about 0.054 mV and dissipates 0.972 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
Stored energy at Isat is about 392 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
K-factor 378 means the flux swing is about 378 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.
The HCMA1104 family spans 0.2 uH to 22 uH; this row sits at position 6 of 12.
The next value up in the same family, HCMA1104-1R5-R, gives 1.5 uH at 16 A and DCR 3.8 mOhm: the extra inductance costs about 6 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 3.3 mOhm becomes roughly 4.66 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.
How does this differ from the commercial HCM part?
Same molded construction and similar body sizes, but automotive qualified, characterised to +125 °C, and wound for higher current in the larger sizes. The electrical rows are not interchangeable.
What current can it carry continuously?
The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.
Is this part suitable for a 48 V rail?
The electrical ratings suit it, but isolation and creepage are board-level decisions. Check terminal spacing and any coating against the rail voltage.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd