Eaton HCMA1104-R36-R 0.36 uH AEC-Q200 Inductor, 30 A
Eaton HCMA1104-R36-R 0.36 uH AEC-Q200 Inductor, 30 A

Eaton HCMA1104-R36-R 0.36 uH AEC-Q200 Inductor, 30 A

Share
Eaton HCMA1104-R36-R: AEC-Q200 high-current inductor, 0.36 uH ±20%, 30 A Irms, Isat 42 A, DCR 1.04 mOhm, 11.5 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCMA1104-R36-R 0.36 uH AEC-Q200 Inductor, 30 A

    HCMA1104-R36-R at a glance: AEC-Q200 high-current inductor, 0.36 uH ±20%, 30 A Irms, Isat 42 A (20% rolloff @ +25 °C), DCR 1.04 mOhm, 11.5 x 10.3 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCMA1104-R36-R
    OCL (open circuit inductance)0.36 uH ±20%
    FLL minimum, at Isat0.23 uH
    Irms (DC, 40 °C rise)30 A
    Isat (20% rolloff @ +25 °C)42 A
    DCR typical @ +20 °C1.04 mOhm
    DCR maximum @ +20 °C1.2 mOhm
    K-factor (Bp-p = K x L x dI)269, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10349

    Dimensions and Pad Layout

    HCMA1104-R36-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10349: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    This is the high-current member of the automotive molded family. Where the standard automotive parts top out at a few tens of amps, this one is built for the main DC-DC stage: thicker winding, larger body, and a saturation current that scales with it.

    Copper loss at the rated current works out to roughly 0.936 W from a typical DCR of 1.04 mOhm at 30 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Energy storage at the saturation current is around 318 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The K-factor of 269 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 96.8 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    What This Family Is For

    The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.

    Within the HCMA1104 family this is value 2 of 12, in a range that runs from 0.2 uH to 22 uH.

    One step down the table, HCMA1104-R20-R, sits at 0.20 uH with 32 A and 0.63 mOhm – the lower inductance buys about 3 A of extra current in the same body.

    • Core material: iron powder core, 11.5 x 10.3 mm body at 4.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tai lamps and interior lighting; heating ventilation and air conditioning con- trollers (hvac); doors, window lift and seat control.
    • Automotive derating practice: size against the saturation current at the hot corner and keep margin for the load transient, not just the steady-state current.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1.2 mOhm becomes roughly 1.7 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.

    • Verify the shielding against the EMC plan for the board.
    • Check the terminal spacing against the rail voltage and the coating scheme.
    • Confirm the terminal spacing against the rail voltage.

    Frequently Asked Questions

    What is the difference between Irms and Isat here?
    Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.

    How does this differ from the commercial HCM part?
    Same molded construction and similar body sizes, but automotive qualified, characterised to +125 °C, and wound for higher current in the larger sizes. The electrical rows are not interchangeable.

    What current can it carry continuously?
    The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message