    HCMA1104-R56-R at a glance: AEC-Q200 high-current inductor, 0.56 uH ±20%, 25 A Irms, Isat 32 A (20% rolloff @ +25 °C), DCR 1.56 mOhm, 11.5 x 10.3 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCMA1104-R56-R
    OCL (open circuit inductance)0.56 uH ±20%
    FLL minimum, at Isat0.36 uH
    Irms (DC, 40 °C rise)25 A
    Isat (20% rolloff @ +25 °C)32 A
    DCR typical @ +20 °C1.56 mOhm
    DCR maximum @ +20 °C1.8 mOhm
    K-factor (Bp-p = K x L x dI)230, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10349

    Outline Drawing

    HCMA1104-R56-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10349: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    This is the high-current member of the automotive molded family. Where the standard automotive parts top out at a few tens of amps, this one is built for the main DC-DC stage: thicker winding, larger body, and a saturation current that scales with it.

    With 1.56 mOhm typical, the I-squared-R loss at the full 25 A rating is about 0.975 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Energy storage at the saturation current is around 287 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The K-factor of 230 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 129 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Positioning in the Range

    The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.

    Of the 12 values listed for HCMA1104, this is the 4th, in a family covering 0.2 uH to 22 uH.

    The next value up in the same family, HCMA1104-R90-R, gives 0.90 uH at 22 A and DCR 2.17 mOhm: the extra inductance costs about 7 A of rated current.

    • Core material: iron powder core, 11.5 x 10.3 mm body at 4.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tai lamps and interior lighting; heating ventilation and air conditioning con- trollers (hvac); doors, window lift and seat control.
    • Automotive derating practice: size against the saturation current at the hot corner and keep margin for the load transient, not just the steady-state current.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1.8 mOhm becomes roughly 2.54 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.

    • Compare against the commercial HCM row of the same size before substituting.
    • Check the current derating at the maximum ambient of the module.
    • Check the terminal spacing against the rail voltage and the coating scheme.

    Frequently Asked Questions

    Can it be used on a 48 V rail?
    The inductance and current ratings suit 48 V converters, but the insulation system and creepage are board-level concerns. Check the terminal spacing and conformal coating against the rail voltage.

    What current can it carry continuously?
    The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.

    What current can it carry continuously?
    The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.