| Parameter | Value |
|---|---|
| Orderable part number | HCMA1104-R90-R |
| OCL (open circuit inductance) | 0.90 uH ±20% |
| FLL minimum, at Isat | 0.58 uH |
| Irms (DC, 40 °C rise) | 22 A |
| Isat (20% rolloff @ +25 °C) | 28 A |
| DCR typical @ +20 °C | 2.17 mOhm |
| DCR maximum @ +20 °C | 2.5 mOhm |
| K-factor (Bp-p = K x L x dI) | 236, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 4.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10349 |

Drawing reproduced from Eaton Technical Data 10349: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded powder core, shielded, AEC-Q200, +125 °C: the part is aimed at automotive DC-DC converters and motor-drive front ends where the inductor carries the full load current and the board has to pass EMC without a shield can.
With 2.17 mOhm typical, the I-squared-R loss at the full 22 A rating is about 1.05 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
Stored energy at Isat is about 353 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
With K = 236, a peak-to-peak ripple of one amp produces roughly 212 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.
Of the 12 values listed for HCMA1104, this is the 5th, in a family covering 0.2 uH to 22 uH.
The next value up in the same family, HCMA1104-1R0-R, gives 1.0 uH at 18 A and DCR 3 mOhm: the extra inductance costs about 7 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 2.5 mOhm becomes roughly 3.53 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.
What is the difference between Irms and Isat here?
Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.
What current can it carry continuously?
The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.
Is it shielded?
Yes – the winding is enclosed in the molded powder core, which keeps the external field low enough for dense automotive boards.