Eaton HCMA1305-1R0-R: AEC-Q200 high-current inductor, 1.00 uH ±20%, 29 A Irms, Isat 50 A, DCR 2.1 mOhm, 13.8 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCMA1305-1R0-R 1.00 uH Molded Automotive Inductor

    HCMA1305-1R0-R at a glance: AEC-Q200 high-current inductor, 1.00 uH ±20%, 29 A Irms, Isat 50 A (20% rolloff @ +25 °C), DCR 2.1 mOhm, 13.8 x 12.5 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCMA1305-1R0-R
    OCL (open circuit inductance)1.00 uH ±20%
    FLL minimum, at Isat0.64 uH
    Irms (DC, 40 °C rise)29 A
    Isat (20% rolloff @ +25 °C)50 A
    DCR typical @ +20 °C2.1 mOhm
    DCR maximum @ +20 °C2.42 mOhm
    K-factor (Bp-p = K x L x dI)275, Bp-p in Gauss
    Package13.8 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10277

    Dimensions and Pad Layout

    HCMA1305-1R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10277: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    The family takes the molded construction used on the commercial high-current parts and applies the automotive qualification and temperature range. Soft saturation and low DCR are the two properties that matter on a 48 V or 12 V rail carrying tens of amps.

    The DCR figure of 2.1 mOhm is what sets the efficiency: at 29 A the winding drops about 0.061 mV and dissipates 1.77 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    Energy storage at the saturation current is around 1,250 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The K-factor of 275 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 275 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Series Positioning

    The HCMA family is the automotive high-current molded range, rated to +125 °C. It shares body sizes with the commercial HCM parts but is qualified and characterised for automotive use, with the current ratings to match the larger winding section.

    The HCMA1305 family spans 0.1 uH to 33 uH; this row sits at position 8 of 21.

    One step down the table, HCMA1305-R82-R, sits at 0.82 uH with 31 A and 1.4 mOhm – the lower inductance buys about 8 A of extra current in the same body.

    • Core material: iron powder core, 13.8 x 12.5 mm body at 5.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • Automotive derating practice: size against the saturation current at the hot corner and keep margin for the load transient, not just the steady-state current.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 2.42 mOhm becomes roughly 3.42 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the AEC-Q200 grade covers the construction, not the thermal design of your board. The loss calculation is still the engineer’s job.

    • Confirm the terminal spacing against the rail voltage.
    • Compare against the commercial HCM row of the same size before substituting.
    • Verify the shielding against the EMC plan for the board.

    Frequently Asked Questions

    Is it shielded?
    Yes – the winding is enclosed in the molded powder core, which keeps the external field low enough for dense automotive boards.

    What is the difference between Irms and Isat here?
    Irms is the DC current for the rated temperature rise; Isat is the peak current at a defined inductance rolloff. A converter can exceed Irms briefly but must stay inside Isat.

    What current can it carry continuously?
    The Irms column, which is the DC current for the stated temperature rise without core loss. Continuous operation also depends on board copper and airflow, so the data sheet derating curves apply.